brakish water micro flow sensor
email: porter@microflowmeter.com Shanghai JSNMicro Flow Meter CO.,LTD has a high-tech talent team who have long been engagedin the design, development, installation and commissioning of automatic controlresearch, and have provided satisfactory sets of systems for variousindustries. With a strong professional team,accumulated a wealth of technology, management experience, covering thecountry"s marketing network and branches, can provide users with fast andconvenient technical services. Since JSN Micro Flow Meter establishment, itrely on Siemens engineer’s powerful technology and high-quality service toquickly gain a good reputation in the instrumentation market. Main products:mircoflow meter,oval gear flow meter , electromagnetic flow meter,piston flowmeter,spur gear flow meter,gear pump,gear metering pump. Adhering to the"build Flow Meter’s aircraft carrier, contribute to China"s automationindustry.

brakish water micro flow sensor
At presentdomestic Oval gear flow meter structure is complex, bulky, bulky, noisy, smallscale, not suitable for low viscosity liquid, the market is more common withDTO series and OGM series. For these problems the country has been unable toovercome, while the Shanghai JiShen instrument Instrument company oval gear Ovalgear flow meter does not have the above problems, such as the same DN25caliber, our model CX-M25-AL, flow range: 0.5 ~ 100L / M, range of 1: 200 orhigher, and weighs only 1.5KG , While the DTO-25, the flow of 600-6000L / H,range ratio of only 1:10, the weight of up to 23KG. All this due totechnological breakthroughs, our chief engineer Tu workers, he is a formerSiemens senior engineer, the use of equipment It is also Siemens CNC MachiningCenter with cutting accuracy up to 0.001mm, which ensures that we produce highquality flow meters.
Ovalgear flow meter is a new type of volumetric flowmeter, in addition to apositive displacement flowmeter with high accuracy, the flow is not sensitiveto other advantages, there are the following advantages: Wide range, usually inthe flow meter is 10: l, and Deep flowmeter is generally 100: 1, or even 1000:1, the accuracy is still above 0.5%, suitable for high pressure flowmeasurement, the maximum pressure can reach 100Mpa, especially suitable for themeasurement of small flow, the minimum measurement limit can be 0.3ml / min ,Less affected by the viscosity characteristics of the medium, suitable for flowmeasurement under various viscosity conditions.

brakish water micro flow sensor
The ovalgear flow meter"s metering principle is the same as that of a generalvolumetric flow meter. The gears mesh with the fluid to be transported. Thefluid to be measured enters the chamber through the oil inlet and pushes therotor so that the fluid is continuously divided into the same volume of fluid.Oil port output. For every one rotation of the rotor, the flowmeter outputs thesame volume of fluid in the four metering chambers in the figure. By measuringthe number of revolutions of the elliptical gear rotor, the volume flow throughthe fluid can be obtained.

brakish water micro flow sensor
Maintechnical data of JSN micro oval Oval gear flow meter
CX-M2,flow range :0.5~150ml/min,accuracy 0.5%,G1/8"
CX-M3, flowrange:3~300ml/min,accuracy 0.5%,G1/8"
CX-M5, flowrange:5~1000ml/min,accuracy 0.5%,G1/8"
CX-M6, flowrange:0.5~100L/H,accuracy 0.5%,G1/4"
CX-M9, flowrange:6~600L/H,accuracy 0.5%,G1/4"
CX-M12,flow range:0.3~30L/Min, accuracy 0.5%,G1/2"
CX-M25,flow range:0.5~100L/Min, accuracy 0.5%,G1"
What are the precautions for the gear flow meter?
1) In the field installation, it should be noted that the direction of the arrow on the flow meter housing is consistent with the flow direction of the fluid;
2) The flowmeter is installed on the same pipe with the same nominal internal diameter as the inlet and outlet fittings. When the pipe is connected with the flowmeter, the seal should not protrude into the fluid;
3) The fluid to be measured shall be filled with the metering room of the flowmeter and the connecting pipes before and after it. If the fluid to be measured contains gas, a gas separator shall be installed before the flowmeter and the filter;